How to Set Multiplier in Monitoring Devices94


Introduction

Setting the multiplier in monitoring devices is a crucial step in ensuring the accurate monitoring of process variables. A multiplier is a numerical factor applied to the raw sensor signal to convert it into the desired engineering units. This article provides a comprehensive guide on how to set the multiplier for various types of monitoring devices, including temperature sensors, pressure transducers, and flow meters.

Understanding the Multiplier

The multiplier is a value that represents the relationship between the raw sensor signal and the desired engineering units. For example, in a temperature sensor, the raw signal may be in millivolts (mV), and the desired engineering unit may be degrees Celsius (°C). The multiplier would then convert the mV reading into the corresponding °C value.

Procedure for Setting the Multiplier

The procedure for setting the multiplier may vary depending on the specific device and its associated software. However, the general steps are as follows:
Identify the Multiplier Setting: Locate the parameter or setting within the device's configuration interface that allows you to set the multiplier.
Determine the Calibration Point: Select a known reference point (e.g., a temperature bath or pressure calibrator) to establish the relationship between the sensor signal and the engineering unit.
Apply the Formula: Calculate the multiplier using the formula: Multiplier = (Known Value) / (Raw Sensor Signal).
Enter the Multiplier: Input the calculated multiplier into the device's configuration interface.
Verify the Setting: Perform a test to ensure the multiplier is set correctly by comparing the displayed value to the known reference value.

Multiplier Setting Examples
Temperature Sensor: If the sensor output is 50 mV, the reference temperature is 100°C, and the desired engineering unit is °F, the multiplier would be (100°F / 50 mV) = 2°F/mV.
Pressure Transducer: Suppose the sensor output is 2 volts (V), the reference pressure is 100 psi, and the desired engineering unit is kPa. The multiplier would be (100 kPa / 2 V) = 50 kPa/V.
Flow Meter: If the sensor output is 10 pulses per second (pps), the reference flow rate is 50 liters per minute (LPM), and the desired engineering unit is cubic meters per hour (m3/h), the multiplier would be ((50 LPM / 10 pps) * 60 minutes/hour) = 300 m3/h/pps.

Conclusion

Setting the multiplier in monitoring devices is critical for accurate data collection and analysis. By following the steps outlined in this guide, users can ensure that their devices are calibrated appropriately, providing reliable and meaningful measurements.